SR-IOV CNI 配置¶
环境要求¶
使用 SR-IOV CNI 需要先确认节点是否为物理主机并且节点拥有支持 SR-IOV 的物理网卡。 如果节点为 VM 虚拟机或者没有支持 SR-IOV 的网卡,那么 SR-IOV 将无法工作。 可通过下面的方式检查节点是否存在支持 SR-IOV 功能的网卡。
检查是否支持 SR-IOV¶
通过 ip link show
获取所有网卡:
root@172-17-8-120:~# ip link show
1: lo: <LOOPBACK,UP,LOWER_UP> mtu 65536 qdisc noqueue state UNKNOWN mode DEFAULT group default qlen 1000
link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00
2: eno1: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq state UP mode DEFAULT group default qlen 1000
link/ether b8:ca:3a:67:e5:fc brd ff:ff:ff:ff:ff:ff
altname enp1s0f0
3: eno2: <NO-CARRIER,BROADCAST,MULTICAST,UP> mtu 1500 qdisc mq state DOWN mode DEFAULT group default qlen 1000
link/ether b8:ca:3a:67:e5:fd brd ff:ff:ff:ff:ff:ff
altname enp1s0f1
4: eno3: <NO-CARRIER,BROADCAST,MULTICAST,UP> mtu 1500 qdisc mq state DOWN mode DEFAULT group default qlen 1000
link/ether b8:ca:3a:67:e5:fe brd ff:ff:ff:ff:ff:ff
altname enp1s0f2
5: eno4: <NO-CARRIER,BROADCAST,MULTICAST,UP> mtu 1500 qdisc mq state DOWN mode DEFAULT group default qlen 1000
link/ether b8:ca:3a:67:e5:ff brd ff:ff:ff:ff:ff:ff
altname enp1s0f3
6: enp4s0f0np0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq state UP mode DEFAULT group default qlen 1000
link/ether 04:3f:72:d0:d2:86 brd ff:ff:ff:ff:ff:ff
7: enp4s0f1np1: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq state UP mode DEFAULT group default qlen 1000
link/ether 04:3f:72:d0:d2:87 brd ff:ff:ff:ff:ff:ff
8: docker0: <NO-CARRIER,BROADCAST,MULTICAST,UP> mtu 1500 qdisc noqueue state DOWN mode DEFAULT group default
link/ether 02:42:60:cb:04:10 brd ff:ff:ff:ff:ff:ff
过滤常见的虚拟网卡(如 docker0、cali*、vlan 子接口等),以 enp4s0f0np0
为例,确认其是否支持 SR-IOV:
root@172-17-8-120:~# ethtool -i enp4s0f0np0
driver: mlx5_core # 网卡驱动
version: 5.15.0-52-generic
firmware-version: 16.27.6008 (LNV0000000033)
expansion-rom-version:
bus-info: 0000:04:00.0 # PCI 设备号
supports-statistics: yes
supports-test: yes
supports-eeprom-access: no
supports-register-dump: no
supports-priv-flags: yes
通过 bus-info
查询其 PCI 设备详细信息:
root@172-17-8-120:~# lspci -s 0000:04:00.0 -v | grep SR-IOV
Capabilities: [180] Single Root I/O Virtualization (SR-IOV)
如果输出有上面此行,说明此网卡支持 SR-IOV。获取此网卡的 vendor 和 device:
其中,
15b3
:表示此 PCI 设备的厂商号,如15b3
表示 Mellanox1017
:表示此 PCI 设备的设备型号,如1017
表示 Mellanox MT27800 Family [ConnectX-5] 系列网卡
可通过
https://devicehunt.com/all-pci-vendors
查询所有 PCI 设备信息。
配置 VF(虚拟功能)¶
通过下面的方式为支持 SR-IOV 的网卡配置 VF:
确认 VF 配置成功:
root@172-17-8-120:~# cat /sys/class/net/enp4s0f0np0/device/sriov_numvfs
8
root@172-17-8-120:~# ip l show enp4s0f0np0
6: enp4s0f0np0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq state UP mode DEFAULT group default qlen 1000
link/ether 04:3f:72:d0:d2:86 brd ff:ff:ff:ff:ff:ff
vf 0 link/ether 00:00:00:00:00:00 brd ff:ff:ff:ff:ff:ff, spoof checking off, link-state auto, trust off, query_rss off
vf 1 link/ether 00:00:00:00:00:00 brd ff:ff:ff:ff:ff:ff, spoof checking off, link-state auto, trust off, query_rss off
vf 2 link/ether 00:00:00:00:00:00 brd ff:ff:ff:ff:ff:ff, spoof checking off, link-state auto, trust off, query_rss off
vf 3 link/ether 00:00:00:00:00:00 brd ff:ff:ff:ff:ff:ff, spoof checking off, link-state auto, trust off, query_rss off
vf 4 link/ether 00:00:00:00:00:00 brd ff:ff:ff:ff:ff:ff, spoof checking off, link-state auto, trust off, query_rss off
vf 5 link/ether 00:00:00:00:00:00 brd ff:ff:ff:ff:ff:ff, spoof checking off, link-state auto, trust off, query_rss off
vf 6 link/ether 00:00:00:00:00:00 brd ff:ff:ff:ff:ff:ff, spoof checking off, link-state auto, trust off, query_rss off
vf 7 link/ether 00:00:00:00:00:00 brd ff:ff:ff:ff:ff:ff, spoof checking off, link-state auto, trust off, query_rss off
输出上图内容,表示配置成功。
安装 SR-IOV CNI¶
通过安装 Multus-underlay 来安装 SR-IOV CNI,具体安装流程参考安装。
注意, 安装时需正确配置 sriov-device-plugin
resource 资源,包括 vendor、device 等信息。
否则 SRIOV-Device-Plugin 无法找到正确的 VF。
配置 SRIOV-Device-Plugin¶
安装完 SR-IOV CNI 之后,通过下面的方式查看 SR-IOV CNI 是否发现了主机上的 VF:
root@172-17-8-110:~# kubectl describe nodes 172-17-8-110
...
Allocatable:
cpu: 24
ephemeral-storage: 881675818368
hugepages-1Gi: 0
hugepages-2Mi: 0
intel.com/sriov-netdevice: 8 # 此行表示 SR-IOV CNI 成功的发现了该主机上的 VFs
memory: 16250260Ki
pods: 110
使用¶
使用 SR-IOV CNI 创建工作负载需要注意下面三个方面:
-
确认 SR-IOV multus network-attachment-definition 对象中存在
sriov-device-plugin
资源:root@172-17-8-110:~# kubectl get network-attachment-definitions.k8s.cni.cncf.io -n kube-system sriov-vlan0 -o yaml apiVersion: k8s.cni.cncf.io/v1 kind: NetworkAttachmentDefinition metadata: annotations: k8s.v1.cni.cncf.io/resourceName: intel.com/sriov_netdevice name: sriov-vlan0 namespace: kube-system
resourceName
必须与注册到kubelet
中的资源名称保持一致(即和 Node 对象中的名称保持一致)。创建 network-attachment-definition 对象后,再更新 annotations:
k8s.v1.cni.cncf.io/resourceName
不会生效! -
创建工作负载时,需要在 Pod 的 annotations 字段中通过 multus 的注解绑定指定的 network-attachment-definition 对象。
-
如果 type 为 sriov-overlay,那么需要在 Pod 的 Annotations 中插入以下的注解:
k8s.v1.cni.cncf.io/networks
:表示会在 Pod 中除默认 CNI 之外再插入一张 SR-IOV CNI 网卡。 -
如果 type 为 sriov-standalone,那么需要在 Pod 的 Annotations 中插入以下的注解:
v1.multus-cni.io/default-network
:修改 Pod 的默认网卡。如果不指定,将通过集群默认 CNI 为 Pod 分配第一张网卡。
-
-
在 Pod 的 Resource 字段中给予容器 SR-IOV 资源配额:
... containers: resources: requests: intel.com/sriov-netdevice: '1' limits: intel.com/sriov-netdevice: '1' ...
名称需要保持一致, 否则 Pod 会因为请求不到 VF 而创建失败。